PXD023334-2
PXD023334 is an original dataset announced via ProteomeXchange.
Dataset Summary
Title | Comparison of unit resolution versus high-resolution accurate mass for parallel reaction monitoring |
Description | Parallel reaction monitoring (PRM) is an increasingly popular alternative to selected reaction monitoring (SRM) for targeted proteomics. PRM’s strengths over SRM are that it monitors all product ions in a single spectrum, thus eliminating the need to select interference-free product ions prior to data acquisition, and that it is most frequently performed on high-resolution instruments, such as quadrupole-orbitrap and quadrupole-time of flight instruments. Here, we show that the primary advantage of PRM is the ability to monitor all transitions in parallel, and that high-resolution data are not necessary to obtain high quality quantitative data. We run the same scheduled PRM assay, measuring 432 peptides from 126 plasma proteins, multiple times on a Orbitrap Eclipse Tribrid mass spectrometer, alternating separate liquid chromatography-tandem mass spectrometry runs between the high resolution Orbitrap and the unit resolution linear ion trap for PRM. We find that both mass analyzers have similar technical precision, and that the linear ion trap’s superior sensitivity gives it better lower limits of quantitation on over 62% of peptides in the assay. |
HostingRepository | PanoramaPublic |
AnnounceDate | 2021-08-19 |
AnnouncementXML | Submission_2021-08-19_08:58:20.125.xml |
DigitalObjectIdentifier | |
ReviewLevel | Peer-reviewed dataset |
DatasetOrigin | Original dataset |
RepositorySupport | Supported dataset by repository |
PrimarySubmitter | Lilian Heil |
SpeciesList | scientific name: Homo sapiens; NCBI TaxID: 9606; |
ModificationList | Carbamidomethyl; Oxidation; Label:13C(6)15N(2); Label:13C(6)15N(4) |
Instrument | Orbitrap Eclipse; Orbitrap Fusion Lumos |
Dataset History
Revision | Datetime | Status | ChangeLog Entry |
---|---|---|---|
0 | 2021-01-02 11:51:35 | ID requested | |
1 | 2021-05-06 09:38:11 | announced | |
⏵ 2 | 2021-08-19 08:58:20 | announced | : Added PubMed Id |
Publication List
Heil LR, Remes PM, MacCoss MJ, Comparison of Unit Resolution Versus High-Resolution Accurate Mass for Parallel Reaction Monitoring. J Proteome Res, 20(9):4435-4442(2021) [pubmed] |
Keyword List
submitter keyword: mass spectrometry, limit of quantitation, precision, PRM |
Contact List
Michael MacCoss | |
---|---|
contact affiliation | University of Washington |
contact email | maccoss@uw.edu |
lab head | |
Lilian Heil | |
contact affiliation | University of Washington |
contact email | lheil2@uw.edu |
dataset submitter |
Full Dataset Link List
Panorama Public dataset URI |