⮝ Full datasets listing

PXD052847

PXD052847 is an original dataset announced via ProteomeXchange.

Dataset Summary
TitleLinear Ion Trap Global to Targeted Proteomics: A workflow for targeted proteomics assay development using a versatile linear ion trap
DescriptionAdvances in proteomics and mass spectrometry have enabled the study of limited cell populations, such as single-cell proteomics, where high-mass accuracy instruments are typically required. While triple quadrupoles offer fast and sensitive nominal resolution measurements, these instruments are effectively limited to targeted proteomics. Linear ion traps (LITs) offer a versatile, cost-effective alternative capable of both targeted and global proteomics. We demonstrate a workflow using a newly released, hybrid quadrupole-LIT instrument for developing targeted proteomics assays from global data-independent acquisition (DIA) measurements without needing high-mass accuracy. Gas-phase fraction-based DIA enables rapid target library generation in the same background chemical matrix as each quantitative injection. Using a new software tool embedded within EncyclopDIA for scheduling parallel reaction monitoring assays, we show consistent quantification across three orders of magnitude of input material. Using this approach, we demonstrate measuring peptide quantitative linearity down to 25x dilution in a background of only a 1 ng proteome without requiring stable isotope labeled standards. At 1 ng total protein on column, we found clear consistency between immune cell populations measured using flow cytometry and immune markers measured using LIT-based proteomics. We believe hybrid quadrupole-LIT instruments represent an economic solution to democratizing mass spectrometry in a wide variety of laboratory settings.
HostingRepositoryPanoramaPublic
AnnounceDate2024-06-19
AnnouncementXMLSubmission_2024-06-19_17:13:51.234.xml
DigitalObjectIdentifier
ReviewLevelPeer-reviewed dataset
DatasetOriginOriginal dataset
RepositorySupportSupported dataset by repository
PrimarySubmitterAriana Shannon
SpeciesList scientific name: Mus musculus; NCBI TaxID: 10090;
ModificationListCarbamidomethyl
InstrumentStellar
Dataset History
RevisionDatetimeStatusChangeLog Entry
02024-06-04 22:01:38ID requested
12024-06-19 17:13:51announced
Publication List
A workflow for targeted proteomics assay development using a versatile linear ion trap. Ariana E. Shannon, Rachael N. Teodorescu, Nojoon Soon, Lilian R. Heil, Cristina C. Jacob, Philip M. Remes, Mark P. Rubinstein, Brian C. Searle bioRxiv 2024.05.31.596891
doi: https://doi.org/10.1101/2024.05.31.596891
Keyword List
submitter keyword: Ion Trap, Stellar MS, DIA, Data-independent acquisition, DDA, High pH reverse phase fractionation, offline fractionation, global proteomics, targeted proteomics, parallel reaction monitoring, prm
Contact List
Brian Searle
contact affiliationThe Ohio State University
contact emailsearleb@gmail.com
lab head
Ariana Shannon
contact affiliationThe Ohio State University
contact emailariana.shannon@osumc.edu
dataset submitter
Full Dataset Link List
Panorama Public dataset URI