<<< Full experiment listing

PXD004394

PXD004394 is an original dataset announced via ProteomeXchange.

Dataset Summary
TitleIntegrated Quantification method for precise and robust protein measurement in clinical proteomics, study 1
DescriptionBackground: Current quantification methods for mass spectrometry (MS)-based proteomics either do not provide sufficient control of variability or are difficult to implement for routine clinical testing. Results: We present here an integrated quantification (InteQuan) method that better controls pre-analytical and analytical variability than the popular quantification method using stable isotope-labeled standard peptides (SISQuan). We quantified 16 lung cancer biomarker candidates in human plasma samples in three assessment studies, using immunoaffinity depletion coupled with multiple reaction monitoring (MRM) MS. InteQuan outperformed SISQuan in precision in all three studies and tolerated a two-fold difference in sample loading. The three studies lasted over six months and encountered major changes in experimental settings. Nevertheless, plasma proteins in low ng/ml to low μg/ml concentrations were measured with a median technical coefficient of variation (CV) of 11.9% using InteQuan. The corresponding median CV using SISQuan was 15.3% after linear fitting. Furthermore, InteQuan surpassed SISQuan in measuring biological difference among clinical samples and in distinguishing benign versus cancer plasma samples. Conclusions: We demonstrated that InteQuan is a simple yet robust quantification method for MS-based quantitative proteomics, especially for applications in biomarker research and in routine clinical testing.
HostingRepositoryPeptideAtlas
AnnounceDate2016-06-20
AnnouncementXMLSubmission_2016-06-20_16:24:12.xml
DigitalObjectIdentifier
ReviewLevelPeer-reviewed dataset
DatasetOriginOriginal dataset
RepositorySupportSupported dataset by repository
PrimarySubmitterLik Wee Lee
SpeciesList scientific name: Homo sapiens; NCBI TaxID: 9606;
ModificationList6x(13)C,4x(15)N labeled L-arginine; 6x(13)C,2x(15)N labeled L-lysine
Instrument6490 Triple Quadrupole LC/MS
Dataset History
RevisionDatetimeStatusChangeLog Entry
02016-06-20 16:20:28ID requested
12016-06-20 16:24:14announced
Publication List
Li XJ, Lee LW, Hayward C, Brusniak MY, Fong PY, McLean M, Mulligan J, Spicer D, Fang KC, Hunsucker SW, Kearney P, An integrated quantification method to increase the precision, robustness, and resolution of protein measurement in human plasma samples. Clin Proteomics, 12(1):3(2015) [pubmed]
Keyword List
curator keyword: selected reaction monitoring, SRM, targeted
Contact List
Lik Wee Lee
contact affiliationIntegrated Diagnostics
contact emailllee@indidx.com
dataset submitter
Paul Kearney
contact affiliationIntegrated Diagnostics
contact emailpkearney@indidx.com
lab head
Full Dataset Link List
PeptideAtlas dataset URI
PASSEL experiment URI
PASSEL transition group browser URI
PASSEL transition group browser URI
PeptideAtlas dataset URI
PASSEL transition group browser URI